Plate-Fix 1.5kN Option Load Detail

AliRail Vertical Infill Plate-Fix 1.5kN Option is load tested in accordance with BS 6180:2011 (1.5kN/m horizontal line load, 1.5kN infill point load, 1.5kN/m2 infill distributed load).

Modern Balustrades, AliRail Top Fix. Front View
Modern Balustrades, AliRail Top Fix. Cross Section
  • Fire resistant: A2-s1, d0
  • Loading performance:
    • Horizontal line load: 1.5kN/m
    • Infill point load: 1.5kN/m
    • Infill distributed load: 1.5kN/m2
  • Coating thickness – 60-80 microns
  • Impact test – with an energy of 2.5Km to ensure that the coating adheres to the substrate to EN ISO 6272 / ASTM D2794
  • Bend test – on 5mm mandrel to ensure adhesion after bending to EN ISO 1519
  • Machu Test (accelerated corrosion test) – in a solution made up of sodium chloride acetic acid and hydrogen peroxide at
    37 degrees C Duration 48 hours
  • Qualicoat 2.4.1. – cross hatch cuts are made at 2mm spacings with one being at 90 degrees to the other cut, tape is the applied
    left for 2 minutes and removed to check
    for adhesion of paint (EN ISO 2409 2013)
  • Qualicoat 2.18 – sawing and drilling test to ensure no flaking after cutting (using sharp tools)
  • Acid salt spray test – ISO 9227 EN ISO 3231 – Resistance to humid
    atmospheres containing Sulphur Dioxide
  • EN ISO 11341 – Accelerated weathering test
  • EN ISO 20810 – Natural weathering test (Florida Test) (Carried out on Powder Type) EN ISO 12206-1 – Resistance to mortar (Carried out on powder type)
  • EN ISO 6270 – 2 – Constant climate condensation water test.
  • Choice of colours – Available in a wide range of RAL colours.

Our modern design metal balustrade Top-Fix method has more connections into the top and underside of the steel frame, so can deliver higher loading performance up to 1.5kN commercial requirements (as proven in independent load-testing to a test rig at our Rochester HQ earlier this year).

The excellent performance of the Top-Fix option provides ample reassurance to specifiers, the result data is indicative only and loading performance for individual balcony designs is the ultimate responsibility of the balcony designer.

Plate-Fix 1.5kN Datasheet & CAD Drawings

Plate-Fix 1.5kN Load Test Result