A-Fence Specification

  • Scroll within the NBS window above to view all content

  • Fire resistant:
    • A2-s1, d0 and A2fl-s1
  • Coating thickness: 60-80 microns
  • Impact test: with an energy of 2.5kN to ensure that the coating adheres to the substrate to EN ISO 6272 / ASTM D2794
  • Bend test: on 5mm mandrel to ensure adhesion after bending to EN ISO 1519
  • Machu Test (accelerated corrosion test): in a solution made up of sodium chloride acetic acid and hydrogen peroxide at 37 ˚C Duration 48 hours
  • Qualicoat 2.4.1.: cross hatch cuts are made at 2mm spacings with one being at 90 degrees to the other cut, tape is the applied left for 2 minutes and removed to check for adhesion of paint (EN ISO 2409 2013)

  • Qualicoat 2.18: sawing and drilling test to ensure no flaking after cutting (using sharp tools)
  • Acid salt spray test: ISO 9227
  • EN ISO 3231: Resistance to humid atmospheres containing Sulphur Dioxide
  • EN ISO 11341: Accelerated weathering test
  • EN ISO 20810: Natural weathering test (Florida Test) (Carried out on Powder Type)
  • EN ISO 12206-1: Resistance to mortar (Carried out on powder type)
  • EN ISO 6270 – 2: Constant climate condensation water test.
  • Available finishes include our 2 standard colours, (RAL 7016 & 9005) all in a sleek powder-coat, providing a range of aesthetically pleasing options to suit any property. Other colours available on request.